Products

Specifications

Three Phase Jog Control Specifications

Motor Size Voltage Height Width Depth Enclosure Mounting
Up to 10 HP 400 VAC/3 PH/60 Hz 20 Inches 16 Inches 6 Inches Wall Mount

NOTE: Dimensions are the same for Momentary or Maintained controls. Dimensions shown are for standard jog controls with a single electric motor.

Three Phase Jog System Control Methods

Method 1 - Momentary Jog Controls

Three-Phase-Momentary-Jog-Controls.jpg

 
  • Press and hold the extend or retract pushbutton.
  • Control voltage is applied to the limit switch.
  • Control voltage from the limit switch energizes the motor starter.
  • The motor starter supplies three phase power to the motor. The motor will run clockwise or counterclockwise to extend or retract the actuator.
 
  • Releasing the extend or retract pushbutton de-energizes the motor starter stopping the motor and actuator.
  • If the normally closed limit switch is activated the motor starter will be de-energized stopping the motor and actuator.

Method 2 - Maintained Jog Controls

Three-Phase-Maintained-Jog-Controls.jpg

 
  • Press and release the extend or retract pushbutton.
  • Control voltage is applied to the limit switch.
  • Control voltage from the limit switch passes through the stop pushbutton and energizes the motor starter.
  • The motor starter supplies three phase power to the motor. The motor will run clockwise or counterclockwise to extend or retract the actuator.
 
  • Pressing the stop pushbutton de-energizes the motor starter stopping the motor and actuator.
  • If the normally closed limit switch is activated the motor starter will be de-energized stopping the motor and actuator.